Refrigeration units play a crucial role in maintaining the quality and safety of stored goods. However, like any other electrical appliance, they can encounter issues. Understanding error codes can help diagnose and troubleshoot problems quickly, reducing downtime and maintenance costs. Below is a comprehensive list of POLAR refrigeration error codes and their meanings to assist you in identifying potential issues and taking the necessary steps for resolution.

| Error Code | Description |
|---|---|
| ER1 | Evaporator inlet probe is faulty |
| ER2 | Evaporator return gas probe is faulty |
| ER3 | Defrost probe (evaporator temperature probe) is faulty |
| ER4 | Door not closed properly or door switch is faulty |
| ER5 | Condenser probe is faulty |
| SO | Cabinet temperature probe is open-circuited |
| SC | Cabinet temperature probe is short-circuited |
| HI | Condenser temperature exceeding 60°C |
| EE | Data or memory failure |
| rPF | Thermostat probe failure |
| EPF | Evaporator probe failure |
| i1P | Insert probe 1 failure |
| i2P | Insert probe 2 failure |
| i3P | Insert probe 3 failure |
| rtC | Clock data lost |
| rtF | Clock failure |
| HA | Maximum temperature alarm |
| LA | Minimum temperature alarm |
| FF | Fast freezing interrupted by short power failure |
| PFA | Fast freezing interrupted by long power failure |
| OCF | Maximum cycle time has been exceeded |
| EA | External alarm |
| CA | Serious external alarm |
| dA | Door open alarm |
| HtA | Inner temperature exceeds the set maximum temperature |
| LtA | Inner temperature exceeds the set minimum temperature |
| PF1 | Short circuit or interruption of the thermostat probe input line |
| PF2 | Short circuit or interruption of the evaporator probe input line |
| HLA | Inner temperature greater than 90°C |
| LLA | Inner temperature lower than -45°C |
| E1 | Faulty air sensor |
| E2 | Faulty defrost sensor |
| E13 | Communication error (cable between the digital readout and the control relay is faulty) |
| VH | Voltage high |
| VL | Voltage low |
Being aware of these error codes can help in the timely identification and resolution of refrigeration system malfunctions. Regular maintenance and prompt attention to these warnings can extend the lifespan of your unit and ensure optimal performance. If an issue persists despite troubleshooting, consulting a professional technician is always recommended. Stay proactive in maintaining your refrigeration system to avoid unexpected breakdowns!
Best in London for Over 20 years

Address:
Office 7, 35/37 Ludgate Hill
London, EC4M 7JN
Expert Insights, Maintenance Tips, and the lates updates on Air Conditioning & Refrigeration.


Address:
Office 7, 35/37 Ludgate Hill
London, EC4M 7JN
Air Conditioning Maintenance & Service


How to Choose the Right Food Retail Refrigeration SystemT&C’s apply
polar fridge freezer, polar refrigeration p1 error, polar fridge, polar fridge problems, polar fridges, polar freezer, polar refrigeration, fridge freezer warning, polar alarm, polar freezers, polar refrigerator, polar commercial fridge
heat pump, air conditioning, roof, indoor air quality, variable refrigerant flow, chiller, air handler, pump, duct, compressor, humidity, ventilation, innovation, condenser, daikin, data center, air purifier, refrigerant, sustainability, dehumidifier, thermostat, brand, heat exchanger, building automation, air filter, trane, hvac, heating, air conditioning maintenance, commercial hvac companies near me, commercial hvac near me, commercial air conditioning companies, commercial hvac service near me, commercial air conditioning companies near me, commercial hvac contractors, commercial hvac contractors near me, hvac commercial companies, commercial air conditioning service, commercial air conditioning, commercial hvac, commercial ac, commercial hvac services, commercial hvac systems, hvac installation commercial, climate, evaporator, furnace, automation, efficiency, water cooling, energy management, factory, knowledge, server room, floor, energy, manufacturing, customer, electronics, exhaust system, consumption, conditioning unit, contractor, hvac systems, air conditioners, air conditioning units, commercial air conditioner, hvac system, services air conditioning, commercial hvac system, hvac solutions, commercial air conditioners, units, commercial ac unit, commercial air conditioning unit, lg commercial hvac, inverter compressor, leak, pressure, valve, sensible heat, liquid, engine, ashrae, standard temperature and pressure, ammonia, heat transfer, heat pump and refrigeration cycle, matter, steel, cryogenics, british thermal unit, freezing, pipe, thermal expansion valve, thermal insulation, environmentally friendly, latent heat, stainless steel, turbine, piston, centrifugal compressor, fluid, american society, volume, evaporative cooler, oil, weight, dairy, boiling, magnet, thermometer, convection, vapor pressure, coolant, molecule, enthalpy, melting point, lubricant, scroll compressor, carbon, experiment, solid, carbon dioxide, machine, vacuum, warranty, meat, metal, absolute zero, radiator, absorption, cold chain, entropy, check valve, international institute of refrigeration, construction, ton of refrigeration, centrifugal fan, thermodynamics, food preservation, second law of thermodynamics, bearing, welding, horsepower, snow, foam, john gorrie, phase, ton, quantity, dry ice, thermal expansion, nutrition, citation, water vapor, laws of thermodynamics, james harrison, alloy, patent, airflow, ratio, pressure drop, cooling tower, heat wave, natural refrigerant, research, sublimation, diethyl ether, room temperature, particle, ferdinand carré, encyclopedia, methane, wood, samsung family hub, r404a, r600a, instaview, samsung twin cooling, r404, r449a, instaview lg, be spoke samsung, foodservice, countertop, global warming potential, hydrofluorocarbon, retail, lighting, food safety, food spoilage
commercial air conditioning, hvac, commercial air conditioning london, commercial air conditioning installation, commercial fridge repair london, air conditioning companies near me, hvac repair, be cool refrigeratio, ac