Many air conditioner noises are normal: clicks from valves and electrics, a buzz as the louvre moves, creaks as plastic parts expand and contract, a rush of water during defrost, and a gentle hum from the fan. Noises worth acting on are new or harsh ones: rattling, grinding, squealing, loud knocking, or a bubbling sound in the drain that Daikin says can be fixed with a check valve. If a unit suddenly sounds wrong, Daikin's advice is to stop it, switch off the power and call for service.
This guide goes through the common sounds, what causes them, and what to do, using the troubleshooting advice Daikin publishes.
At a glance
| Sound | Usual cause | Normal? |
|---|---|---|
| Clicking | Refrigerant control valve or electrical components switching | Yes |
| Buzzing as the louvre moves | Flap motor | Yes |
| Rattling or creaking at start or stop | Flap adjusting, plastic parts expanding with temperature | Yes |
| Flowing water or hissing in heating, then a pause | Outdoor unit defrosting | Yes |
| Hissing or crackling on units with an air purifier | Streamer discharge (Daikin) | Yes |
| Bubbling or knocking from the drain | Outside air pulled back through the drain hose | Fixable, often with a check valve |
| Rattling, grinding or squealing during running | Loose panel, debris in a fan, worn fan motor | No |
| Loud humming or knocking from the outdoor unit | Compressor, fan or mounting problem | No |
Normal air conditioner sounds
Daikin's troubleshooting guide lists several sounds that are not faults:
- Clicking, which Daikin says may be produced when the refrigerant control valve or an electrical component operates.
- Buzzing when the flap moves.
- Rattling or creaking when the flap position is adjusted during start-up or stopping.
- Water flowing when heating stops unexpectedly. Daikin explains that the outdoor unit is defrosting, which takes about 3 to 10 minutes.
- Hissing or crackling on Daikin models with a Streamer air purifier, which Daikin says comes from the Streamer discharge and is not a malfunction.
Fans and compressors also make a steady hum and a whoosh of air, which gets louder at higher fan speeds. Inverter units are usually quieter, because they slow the compressor down rather than switching it on and off. Our guide to inverter air conditioning explains why.
Bubbling or knocking from the drain
Daikin explains that when a room is completely closed and an extract fan is running, or strong winds are blowing outside, outdoor air can be drawn in through the drain hose and cause a bubbling sound, especially in well-sealed homes and flats. Its suggestions are to open a room vent or a window, turn off the extract fan, or point the end of the drain hose in a different direction. For thumping and knocking sounds, Daikin says a drain hose check valve can stop air flowing back in, and that the installer can fit one.
Noises that need attention
- Rattling while running. A loose front panel, grille or cover, or something touching the unit. On the outdoor unit, a loose cover or mounting bolts, or debris caught in the fan.
- Grinding or scraping. Usually a fan blade catching on something, or a failing fan motor bearing.
- Squealing or screeching. Worn fan motor bearings, which get worse over time.
- Loud humming or buzzing from the outdoor unit with poor cooling, which can point to the compressor or its start components.
- Knocking or banging from the outdoor unit as the compressor starts or stops, which can point to worn mountings or a compressor problem.
- A gurgle with poor cooling that does not match the drain behaviour above, which can point to a refrigerant problem.
For any of these, Daikin's advice for an abnormal noise during operation is to stop the unit, switch off at the breaker, and contact the installer or service provider. Our air conditioning repair engineers diagnose noisy units across London.
What you can check safely
- Work out whether the noise comes from the indoor or outdoor unit, and when: at start-up, while running, or at stopping.
- Check the front panel and filters are clipped in properly.
- Look for anything touching or resting on the indoor unit, and for leaves, twigs or rubbish around the outdoor unit.
- For drain bubbling, try Daikin's suggestions: open a window or vent, or turn off an extract fan.
- Clean the filters. Dirty filters make the fan work harder and noisier.
Do not open the outdoor unit or reach into a fan. Switch off at the breaker if a noise is loud or getting worse.
Outdoor unit noise and neighbours
Outdoor units are the noisier half of a system, and their noise matters to neighbours as well as to you. For air-to-air heat pumps installed under permitted development in England, MCS 020(a) sets a limit of 37 dB measured at the nearest neighbouring window. Our guide to planning permission for air conditioning explains the rules. A unit that has become noisier over time often just needs its fan, mountings and coil checked during a service.
Planned air conditioning maintenance catches worn fan bearings, loose panels and mounting problems before they get loud.
Questions people ask about air conditioner noises
Why is my air conditioner so noisy?
Common causes are a loose panel or filter, dirty filters making the fan work harder, debris in the outdoor fan, or worn fan bearings. Some sounds, such as clicking, creaking and defrost water, are normal, as Daikin explains.
Is it normal for an air conditioner to click?
Yes. Daikin says clicking may be produced when the refrigerant control valve or electrical components operate. Constant rapid clicking with no cooling is worth having checked.
Why does my air conditioner make a bubbling or gurgling noise?
Often because outside air is being drawn in through the drain hose, which Daikin says happens in well-sealed rooms or in strong wind. Opening a window or vent helps, and a drain hose check valve can stop it.
Why does my air conditioner make a water noise in heating mode?
The outdoor unit is defrosting. Daikin says heating may stop with a sound of flowing water for about 3 to 10 minutes, and that this is normal.
Why is my air conditioner rattling?
Check the front panel and filters are seated, nothing is touching the unit, and no debris is in the outdoor unit. A rattle that continues during running may be a loose part or a fan fault that needs an engineer.
Are inverter air conditioners quieter?
Usually, because the compressor slows down to hold the temperature rather than switching on and off at full power, so there are fewer loud starts and stops.
The short version
Clicks, creaks, louvre buzz and defrost water are normal. Drain bubbling can usually be fixed. Rattling, grinding, squealing or loud knocking means a part is loose or wearing, so switch off and have it checked before it fails.
Last updated: 4 November 2026

Written by
Ali Elm
Ali is the Head of Operations at Be Cool Refrigeration with over a decade of hands-on experience in HVAC and commercial refrigeration. He oversees every installation, repair, and maintenance project, making sure the work meets the highest standards. Ali holds full F-Gas certification and has worked across residential, commercial, and industrial refrigeration systems throughout London and the South East. When he is not on site, he writes these guides to help business owners and homeowners understand their cooling systems better.