Ice-O-Matic Error Codes: CIM Light Codes Explained

Ice-O-Matic Error Codes: CIM Light Codes Explained
Ali ElmIce Machine

Ice-O-Matic CIM cube ice machines do not show text codes. They report errors by flashing the red POWER light and the yellow CLEAN light in set patterns, which Ice-O-Matic numbers Error 1 to Error 7. A quick red flash on current boards points to a maximum freeze time, a double red flash to a maximum harvest time, and a triple red and triple yellow flash to a water level error.

Lists of "Ice-O-Matic E01 to E05 codes" do not match anything in Ice-O-Matic's own documents, and the meaning of some flash patterns changed when Ice-O-Matic revised the CIM control board in 2021. The tables below come from Ice-O-Matic's current service manuals.

At a glance

Light pattern (current CIM boards)Ice-O-Matic errorWhat it means
POWER flashes red quicklyError 1Maximum freeze time reached
POWER flashes slowly, unit offError 2Thermistor failure
POWER red and CLEAN yellow flash quicklyError 3Maximum fill time reached
Double red and double yellowError 4Maximum purge time reached
Double redError 5Maximum harvest time reached
Triple redError 6Maximum freeze and maximum harvest
Triple red and triple yellowError 7Water level error, the float did not close

Source: Ice-O-Matic Technical Service Manual for Modular CIMs, Elevation Series.

How to read the lights

The POWER and CLEAN lights appear on the push pad on the front of the machine and on the control board buttons. Ice-O-Matic's CIM service manual defines the patterns precisely: SOLID is on constantly, SLOW flashes once every second, QUICK once every half second, DOUBLE flashes twice then pauses for a second, TRIPLE flashes three times then pauses, and DELAYED flashes once every three seconds.

Some lights are normal. A solid red light means the machine is off, solid blue means it is freezing or harvesting normally, and a slow blue flash means it has stopped because the bin is full and will not restart for three minutes, to protect the compressor from short cycling.

Ice-O-Matic CIM error codes

These are the errors listed in Ice-O-Matic's current service manual for Elevation Series CIM modular cubers.

ErrorLight patternWhat Ice-O-Matic says it means
Error 1POWER LED quick flash redUnit has experienced a MAX Freeze (1 hr.). On boards before serial 2106, the same pattern also covered MAX Harvest or both
Error 2POWER LED slow flash in off state onlyThermistor failure
Error 3POWER LED flashes red and CLEAN LED flashes yellow quicklyThe unit experienced a MAX Fill (5 min) on current production. On boards before serial 2106, this was Max Fill and/or Max Purge
Error 4Double red and double yellow quick flashUnit has experienced a MAX Purge (2 min.)
Error 5Double red quick flashUnit has experienced a MAX Harvest (7.5 min)
Error 6Triple red quick flashUnit has experienced MAX Freeze (1 hr.) and Max Harvest (7.5 min)
Error 7Triple red and triple yellow quick flashUnit has experienced a Water Level Error (float did not close)

Why the same lights can mean different errors

Ice-O-Matic revised the CIM control board in 2021, and its service manual marks where the meanings changed. On boards before serial 2106, Error 1 covered a maximum freeze, a maximum harvest or both, and Error 3 covered a maximum fill and/or a maximum purge. Current boards split those into separate errors, which is why the manual now lists Errors 4 to 7. If your machine is older, the serial number on its rating plate decides which description applies.

Clearing codes and running diagnostics

According to the CIM service manual, holding the POWER and CLEAN buttons together for 3 seconds clears error codes and resets the counters, confirmed by a single blue and yellow flash, and holding them for 6 seconds runs the diagnostics program. Ice-O-Matic's CIMU undercounter manual describes the same button combination for resetting error codes.

Clearing an error does not fix its cause. Ice-O-Matic notes, for example, that if the high-pressure cut-out opens during the freeze cycle, the unit may go into Error 1 because the freeze cycle ran too long. That is a refrigeration fault, not something a reset will solve. If the same pattern comes back, call an engineer.

GEM and MFI nugget and flake machines

Ice-O-Matic's flake and nugget machines use indicator lights rather than numbered errors. The GEM, MFI and HEM service manual describes:

LightWhat Ice-O-Matic says it means
Service light blinkingThe auger drive motor current became excessive, so the compressor and auger motor were switched off. The control board restarts the auger motor in 4 minutes and returns to normal if the current stays within limits
Service light glowing continuouslyThe auger motor current was still excessive after a second restart, so the machine has shut down and must be manually reset
WTR-OK light outThe water level in the reservoir has fallen below the sensor, so the machine has shut down. It restarts when the reservoir refills
Bin Full light onNormal. Ice has built up and blocked the bin sensors for 6 seconds or longer, so the machine has stopped

What you can check safely

  • Water supply. A water level or fill error often starts with a closed valve, a kinked supply line or low pressure.
  • Airflow. Air-cooled machines need clear space around the condenser, and a hot, cramped location lengthens freeze cycles.
  • Cleaning. Scale and slime on the evaporator slow freezing and harvest. Follow the manual's cleaning procedure, and do not mix cleaner and sanitiser, which Ice-O-Matic warns against.
  • Power and water off first. Ice-O-Matic's instruction is to always disconnect electrical power and shut off the water supply whenever maintenance or repairs are carried out.

Some current Ice-O-Matic machines run on R-290, which Ice-O-Matic describes as refrigerant grade propane, highly flammable and heavier than air. Refrigerant work on these machines is for qualified engineers only. Our guide to ice machine hygiene and cleaning covers the routine that prevents many freeze and harvest errors.

When to call an engineer

  • A thermistor failure (Error 2).
  • Repeated maximum freeze or harvest errors after cleaning and checking the water and airflow.
  • A GEM or MFI service light glowing continuously, which means the machine has shut down on auger motor protection.
  • Any suspected refrigerant fault, especially on propane machines.

Our ice machine repair team works on commercial ice machines across London. If the machine runs but produces little or no ice, see our guide to ice machines that stop making ice.

Questions people ask about Ice-O-Matic error codes

What do the flashing lights mean on an Ice-O-Matic ice machine?

On CIM cubers, the red POWER and yellow CLEAN lights flash in set patterns to show Error 1 to Error 7, such as a quick red flash for a maximum freeze time or a triple red and triple yellow flash for a water level error. Solid blue is normal running, and a slow blue flash means the bin is full.

What is Error 1 on an Ice-O-Matic?

On current CIM boards, Error 1 is a POWER light quick red flash, meaning the unit has reached its maximum freeze time of one hour. On boards before serial 2106, the same pattern also covered a maximum harvest time.

How do I reset an Ice-O-Matic error code?

Ice-O-Matic's CIM service manual says holding the POWER and CLEAN buttons together for 3 seconds clears error codes and resets the counters. Clearing the code does not fix its cause, so call an engineer if it returns.

Are there E01 to E05 codes on Ice-O-Matic machines?

We could not find E01 to E05 codes in any Ice-O-Matic document. CIM cubers use numbered errors shown as light patterns, and flake and nugget machines use indicator lights, so check the service manual for your model.

What does the blinking service light mean on an Ice-O-Matic flake machine?

On GEM and MFI machines, a blinking service light means the auger motor current became excessive and the machine stopped to protect itself. It restarts the auger after 4 minutes. If the light then glows continuously, the machine has shut down and needs a manual reset and an engineer's check.

Getting the right diagnosis

With Ice-O-Matic, the light pattern, the board revision and the model all matter, so note the serial number and the exact pattern before you call. It lets an engineer arrive with the right parts rather than starting from scratch.

Last updated: 4 November 2026

Ali Elm, Head of Operations at Be Cool Refrigeration

Written by

Ali Elm

Ali is the Head of Operations at Be Cool Refrigeration with over a decade of hands-on experience in HVAC and commercial refrigeration. He oversees every installation, repair, and maintenance project, making sure the work meets the highest standards. Ali holds full F-Gas certification and has worked across residential, commercial, and industrial refrigeration systems throughout London and the South East. When he is not on site, he writes these guides to help business owners and homeowners understand their cooling systems better.