Most modern air conditioners in the UK are heat pumps, so in winter they can heat as well as cool. To get the best from yours: keep the filters clean, keep the outdoor unit clear of leaves, snow and ice, expect a short pause while it defrosts, and do not turn the breaker off if you are still using it. If you will not use it all winter, Daikin suggests drying the unit thoroughly before switching off at the breaker.
This guide covers using air conditioning for heating, what is normal in cold weather, how to look after the outdoor unit, and what to do before a long break.
At a glance
| Tip | Why |
|---|---|
| Use heat mode for heating | Reversible air conditioners are air-to-air heat pumps |
| Keep the filters clean | Daikin recommends every 2 weeks while in use |
| Keep the outdoor unit clear | Leaves, snow and ice block airflow and drainage |
| Expect defrost pauses | Heating stops for a few minutes while the outdoor unit defrosts |
| Give it a few minutes at start-up | Daikin says warm air takes about 3 minutes to come through |
| Before a long break, dry the unit then switch off | Stops moisture and mould building up inside |
Heating with air conditioning
A reversible air conditioner is an air-to-air heat pump. In heat mode, it takes heat from the outside air, even on cold days, and moves it indoors. HMRC treats most air conditioning units as air source heat pumps, and the government's Boiler Upgrade Scheme offers £2,500 towards an air-to-air heat pump in eligible homes. Our guides to heat pumps and air conditioning and air-to-air heat pump grants explain more.
Heating with an air-to-air heat pump can be efficient, because it moves more heat than the electricity it uses. Our guide to air conditioning running costs shows how to estimate what it costs.
What is normal in cold weather
Daikin's troubleshooting guide explains several things that happen in winter and are not faults:
- Warm air takes a few minutes. When heating starts, the unit warms up first. Daikin says to wait about 3 minutes.
- Heating stops with a sound of running water. The outdoor unit is defrosting, which Daikin says takes about 3 to 10 minutes.
- Water or steam from the outdoor unit. Daikin says that during heating, the outdoor unit melts the frost that builds up on it and discharges it as water or steam.
Fujitsu says the same about its units: in heating mode, when frost forms on the outdoor unit, the air conditioner stops and defrosts automatically for up to 15 minutes, and the operation indicator blinks while it does.
Looking after the outdoor unit in winter
- Keep it clear. Brush away leaves and snow from around and on top of the unit, and keep the air inlet and outlet free.
- Let it drain. Defrost water needs to run away from the base. If it pools and freezes under the unit, it can build up ice. A drain or a raised mounting helps.
- Do not chip at ice. If ice builds up on the coil, leave it for the defrost cycle. Never use sharp tools or boiling water on the fins.
- Do not cover it while it is running. A cover blocks the airflow the unit needs. If you cover it for a long break, use one designed for the purpose and remove it before switching on.
Inside: comfort and efficiency
- Clean the filters about every 2 weeks while the unit is in use, as Daikin recommends.
- Set a steady temperature rather than turning the unit on and off. Inverter units are most efficient when they run gently and continuously.
- Point the louvres down in heat mode, because warm air rises.
- Keep doors and windows closed in the rooms you are heating.
If you are not using it this winter
Daikin's advice for a long period without use is to run the unit's mould-proof or drying operation on a dry day to let the inside dry thoroughly, then switch off at the circuit breaker and remove the batteries from the remote. Our guide to air conditioners that smell musty explains why drying matters.
Commercial systems in winter
Offices and shops often need cooling and heating in different areas at the same time in winter, especially server rooms, south-facing offices and busy shop floors. Heat recovery VRF systems can move heat from areas that need cooling to areas that need heating. Our guide to VRF air conditioning explains how. Server rooms need cooling all year, and our guide to server room cooling covers low ambient operation.
Winter servicing
Winter is a good time to have a system serviced before the busy summer season, and a service checks the defrost, drainage and heating performance as well as cooling. Planned air conditioning maintenance covers both, and our air conditioning repair engineers deal with heating faults across London. When summer approaches, our guide to preparing air conditioning for summer covers the next steps.
Questions people ask about air conditioning in winter
Can I use my air conditioner for heating in winter?
Yes, if it is a reversible system, which most modern split units are. In heat mode it works as an air-to-air heat pump, taking heat from outside air and moving it indoors.
Why does my air conditioner stop heating for a few minutes?
It is defrosting the outdoor unit. Daikin says heating may stop with a sound of running water for about 3 to 10 minutes, and that this is normal.
Why is there steam coming from my outdoor unit?
During heating, the outdoor unit melts frost and discharges it as water or steam, as Daikin explains. It is part of the normal defrost cycle.
Should I turn off my air conditioner in winter?
If you are using it for heating, no. If you will not use it all winter, Daikin suggests running its drying or mould-proof operation first, then switching off at the breaker.
Should I cover my outdoor unit in winter?
Not while it is in use, because it needs airflow to heat. If it will not be used for a long period, a purpose-made cover can keep debris off, but remove it before switching back on.
The short version
Use heat mode, keep the filters clean and the outdoor unit clear, and let the defrost cycle do its job. If the system is off for the winter, dry it first, switch off at the breaker, and book a service before summer.
Last updated: 4 November 2026

Written by
Ali Elm
Ali is the Head of Operations at Be Cool Refrigeration with over a decade of hands-on experience in HVAC and commercial refrigeration. He oversees every installation, repair, and maintenance project, making sure the work meets the highest standards. Ali holds full F-Gas certification and has worked across residential, commercial, and industrial refrigeration systems throughout London and the South East. When he is not on site, he writes these guides to help business owners and homeowners understand their cooling systems better.